5.
Position hose (8) on water outlet (3). Secure with new
clamp (7).
6.
Install alternator support (2) to water outlet (3) and
install alternator (1) to support (2).
7.
Position support (2) on water outlet (3) and secure
with three capscrews (6). Torque capscrews to 6 lb-ft
(8 Nm).
8.
Align alternator (1) with support (2).
6
9.
Secure alternator (1) to support (2) with capscrew (4)
and nut (5).
8
4
7
2
5
1
3
409-238
10.
Install drive belt to alternator pulley (WP 0061 00).
11.
Connect battery cables (WP 0107 00).
12.
Fill engine cooling system with coolant (WP 0053 00).
END OF WORK PACKAGE