NOTE: USE A SUITABLE PULLER
AND REMOVE PULLEY
AND HUB.
TA031855
Bracket
a. Removal.
(1) Move the radiator fan control lever (fig. 2-1) to
the ON position. In this position the spring is short-
ened, which will permit the spring loop to be pulled
from the bracket with relative ease. Remove the fan
a. Removal.
guard (para. 4-27).
(1) Remove the fan blade (para. 4-29).
(2) Refer to figure 4-17 and remove the fan belt
(2) Refer to figure 4-16 and remove the pulley and
tension control, spring and bracket pulley.
hub.
b. Cleaning and Inspection.
b. Cleaning and Inspection.
(1) Clean all parts with dry cleaning solvent (P-
(1) Clean the pulley and hub with an approved
D-680) and dry thoroughly.
cleaning solvent.
(2) Inspect for cracks, rust and breaks. Replace
(2) Inspect the pulley and hub for cracks and
defective parts.
breaks, Replace a defective pulley and hub.
c. Installation.
c. Installation.
(1) Refer to figure 4-17 and install the fan belt
(1) Refer to figure 4-16 and install the pulley and
tension control, spring and bracket pulley. Install the
hub.
fan guard.
(2) Install the fan blade (para. 4-29).
|