Click here to make tpub.com your Home Page

Page Title: Figure 4-40. Water Pump and Fan Blade, Removal and Installation
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-632-12
Figure 4-40. Water Pump and Fan Blade, Removal and Installation
WARNING
shaft. It must rotate freely, without catching or binding.
Replace a damaged water pump.
Dry cleaning solvent, P-D480, used to clean
(3)
Inspect the fan blade for cracks,
parts is potentially dangerous to personnel
distortion, loose fan elements, and other damage;
and  property.
Avoid  repeated  and
replace a damaged fan blade.
prolonged skin contact.  Do not use near
c. Reassembly and Installation.
open flame or excessive heat. Flash point
(1) Reassemble and install the water pump
of solvent is 100F.-138F. (38C.-60C.).
b. Cleaning and Inspection.
and fan blade as shown in figure 4-40.  Use a new
gasket at installation. Torque cap screws to 25 to 30
(1) Discard and replace the gasket. Clean
foot-pounds torque.
the parts with a cloth dampened with dry cleaning
(2) Install and adjust the fan and generator
solvent P-D-680; dry thoroughly.
drive belts (para 4-55).
(2)  Inspect the water pump for cracks,
signs of leaking, and other damage.  Turn the pump
4-55

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business