Click here to make tpub.com your Home Page

Page Title: CHAPTER 8 REPAIR OF ELECTRIC MOTORS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-631-34
CHAPTER 8
REPAIR OF ELECTRIC MOTORS
Section I. DRIVE MOTOR
8-1. Description
a. The drive motor is a flange mounted, direct
current series wound motor.  The armature has a
replaceable  shaft  with  a  sealed  bearing  at  the
commutator end and a double row thrust bearing at the
drive end.
b. Dual metal graphite brushes are supported in
fixed box type holders to assure proper brush alinement.
A metal clip on top of each brush forms a stop device
that prevents commutator scoring.
8-2. Repair of Drive Motor
a. Brush Replacement.
(1) Remove the floor and toe plates. Remove
drip pan.
(2) Disconnect  the  battery  receptacle  and
discharge the capacitors.
(3) Remove rear cover from drive motor.
Remove brush retaining screws (fig.  8-1).  Lift brush
springs (fig. 8-1) and remove brushes from holders.
Figure 8-1. Drive motor brush location.