|
|
TM 10-3930-673-34
(c)
Slide gland (9) onto rod (8).
(d)
Lubricate piston (15) inner diameter with clean
hydraulic oil. Install new preformed
packing (16) inside bore of piston.
WARNING
Drycleaning Solvent (P-D-680) is
TOXIC and flammable. Wear
protective goggles and gloves; use
only in a well-ventilated area; avoid
contact with skin, eyes, and clothes;
and do not breathe vapors. Keep away
from heat or flame. Never smoke when
using solvent; the flashpoint for type I
drycleaning solvent is 100F (38C),
type II is 138F (59C), and type III is
200F (93.3C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes, immediately
flush eyes with water and get immediate medical attention.
(e)
Use drycleaning solvent and lint-free rag to clean threads on rod (8) and new nut (14).
(f)
Slide piston (15) onto rod (8).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or death, keep away from open fire and use in a well-
ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water.
(g)
Apply sealing compound on threads of rod (8) and nut (14). Install nut on rod.
(h)
Place rod (8) and piston assembly on suitable supports to prevent damage during assembly.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |