15
15-6. AIR CONDITIONER EVAPORATOR COIL REPLACEMENT
This Task Covers:
a. Removal
c. Inspection
b. Cleaning
d. Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool Kit, General Mechanic's: Automotive
Expansion valve removed (Para 15-5)
(Item 23, Appendix D)
Materials/Parts
Safety Glasses
a. Removal. Remove evaporator coil (1)
from heater coil (2) and base (3).
WARNING
Compressed air used for cleaning
TR00004
purposes will not exceed 30 psi
(207 kPa). Use only with effective
chip guarding and personal
1
protective equipment (goggles/
shield, gloves, etc.).
b. Cleaning. Clean evaporator coil (1) with
2
3
low pressure compressed air.
c. Inspection. Check evaporator coil (1) for
cracks, breaks, bent fins, or other obvious
signs of leakage. Replace leaking or
damaged condenser coil.
d. Installation. Install evaporator coil (1) on
base (3) and heater coil (2).
NOTE
Follow-on Maintenance:
Install expansion valve (Para 15-5).
Replace receiver drier (Para 15-7).
END OF TASK