TM 10-3930-673-20-1
40. TRANSMISSION FLUID TEMPERATURE GAGE DOES NOT OPERATE (CONT).
5
KNOWN INFO
TEST OPTIONS
No transmission fluid temperature
Continuity test.
Is continuity present on
reading.
STE/ICE-R #91.
wire 19 between transmission
Wire 10 OK.
REASON FOR QUESTION
fluid temperature gage and
Transmission fluid temperature
If continuity is not present, wire 19
gage OK.
connector J1-14?
or connector J1 faulty.
POSSIBLE PROBLEMS
Wire 19 faulty.
Connector J1 faulty.
Connector P1 faulty.
Repair wire 19 or
NO
connector J1
(Para 8-48).
YES
6
KNOWN INFO
TEST OPTIONS
No transmission fluid temperature
Continuity test.
Is continuity present on
reading.
STE/ICE-R #91.
wire 19 between transmission
Wire 10 OK.
REASON FOR QUESTION
fluid temperature transducer
Connector J1 OK.
If continuity is not present, wire 19
and connector P1-14?
POSSIBLE PROBLEMS
or connector P1 faulty.
Connector P1 faulty.
Wire 19 faulty.
Repair wire 19 or
NO
connector P1
(Para 8-49).
YES
Replace transmission
fluid temperature
transducer
(Para 8-16).
2-572
|