TM 10-3930-673-20-1
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Disconnect connector J1 from
connector P1.
(3) Set multimeter to ohms.
(4) Connect multimeter positive lead (+) to
wire 19 where wire 19 connects to
transmission fluid temperature gage.
WIRE 19
(5) Connect multimeter negative lead () to
connector J1-14.
(a) If continuity is present, go to Step 6
of this fault.
(b) If continuity is not present, repair
wire 19 (Para 8-48) or
connector J1 (Para 8-48).
WIRE 19
CONTINUITY TEST
TRANSDUCER
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Disconnect connector J1 from
connector P1.
(3) Set multimeter to ohms.
(4) Connect multimeter positive lead (+) to
wire 19 where wire 19 connects to
trans fluid temp transducer.
J1-14
(5) Connect multimeter negative lead () to
P1-14
connector P1-14.
(a) If continuity is present, replace
transmission fluid temperature
transducer (Para 8-16).
(b) If continuity is not present, repair
wire 19 or connector P1
(Para 8-49).
CONNECTOR
J
(6) Connect negative battery cable to
1
negative side of battery.
(7) Install battery cover (Para 8-42).
CONNECTOR P1
CONNECTOR
J
1
CONNECTOR P1
TR01492
2-573
|