TM 10-3930-673-20-1
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive lead (+) to
transmission fluid temperature gage
where wire 19 connects.
(3) Connect multimeter negative lead () to
known good ground.
(4) Turn engine start switch to START
position, (TM 10-3930-673-10).
(a) If voltage is present, replace
transmission fluid temperature
gage (Para 8-6).
(b) If voltage is not present, go to
Step 5 of this fault.
(5) Turn engine start switch to OFF
position (TM 10-3930-673-10).
VOLTAGE TEST
(1) Set multimeter to volts dc.
(2) Connect multimeter positive lead (+) to
trans fluid temp transducer where wire
19 connects.
(3) Connect multimeter negative lead () to
known good ground.
(4) Turn engine start switch to START
position, (TM 10-3930-673-10).
(a) If voltage is present, replace
transmission fluid temperature
transducer (Para 8-16).
(b) If voltage is not present, go to
Step 5 of this fault.
(5) Turn engine start switch to OFF
position (TM 10-3930-673-10).
TR01485
2-571
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |