TM 10-3930-673-20-1
24. HIGH TRANSMISSION TEMPERATURE INDICATOR DOES NOT OPERATE (CONT).
4
KNOWN INFO
TEST OPTIONS
High transmission temperature.
Resistance check.
Are 115 to 140 ohms
Other gage lights work.
REASON FOR QUESTION
measured across
12 vdc present at socket.
If correct resistance is not
transmission temperature
Bulb OK.
measured, transmission
switch stabilized at 200F
POSSIBLE PROBLEMS
temperature switch is faulty.
(93.3C) for 15 minutes?
Transmission temperature switch
faulty.
Wire 18 faulty.
Wire 2 faulty.
Replace transmission
NO
temperature switch
(Para 8-16).
YES
5
KNOWN INFO
TEST OPTIONS
High transmission temperature.
Continuity check.
Is continuity present across
Other gages work.
STE/ICE-R #91.
wire 18?
12 vdc present at socket.
REASON FOR QUESTION
Bulb OK.
If continuity is not present across
Transmission temperature switch
wire, wire is faulty.
OK.
POSSIBLE PROBLEMS
Wire 18 faulty.
Wire 2 faulty.
Repair or
NO
replace wire 18
(Para 8-48).
YES