TM 10-3930-673-20-1
CONTINUITY CHECK
(1) Set multimeter to ohms.
(2) Connect multimeter positive lead (+) to
center conductor of bulb.
(3) Connect multimeter negative lead () to
bulb ground.
(a) If continuity is present, go to Step 3
of this fault.
(b) If continuity is not present, replace
CENTER
lens/bulb (Para 8-9).
CONDUCTOR
BULB GROUND
HIGH TRANSMISSION
TEMPERATURE
INDICATOR
OUTSIDE
CONDUCTOR
CONTINUITY CHECK
(1) Set multimeter to ohms.
(2) Connect multimeter positive lead (+) to
outside conductor of high transmission
temperature indicator.
(3) Connect multimeter negative lead () to
known good ground.
(a) If continuity is present, replace
lens/bulb (Para 8-9).
(b) If continuity is not present, go to
Step 4 of this fault.
TR01504
2-405
|