TM 10-3930-673-20-1
24. HIGH TRANSMISSION TEMPERATURE INDICATOR DOES NOT OPERATE (CONT).
2
KNOWN INFO
TEST OPTIONS
High transmission temperature.
Continuity check.
Is continuity present across
Other gage lights work.
STE/ICE-R #91.
high transmission
POSSIBLE PROBLEMS
REASON FOR QUESTION
temperature lens/bulb?
Bulb faulty.
If continuity is not present, replace
Transmission temperature switch
bulb.
faulty.
Wire 18 faulty.
Wire 2 faulty.
Replace light bulb
NO
(Para 8-9).
YES
3
KNOWN INFO
TEST OPTIONS
High transmission temperature.
Continuity check.
Is continuity present between
Other gages work.
STE/ICE-R #91.
high transmission
12 vdc present at socket.
REASON FOR QUESTION
temperature indicator light
Bulb OK.
This question determines where
socket outside conductor and
POSSIBLE PROBLEMS
troubleshooting continues.
known good ground?
Transmission temperature switch
faulty.
Wire 18 faulty.
Wire 2 faulty.
Go to Step 4 of this
NO
fault.
YES
Go to Step 1 of this
fault.
2-404
|