5. INSTRUMENT PANEL GAGE LIGHTS DO NOT OPERATE (CONT).
KNOWN INFO
TEST OPTIONS
14
Bulb(s) OK.
Visual inspection.
Is spacing of grounding fins
Connector P2 OK.
REASON FOR QUESTION
Connector J2 OK.
correct for proper ground?
If grounding fins are not evenly
Wire 9 OK.
spread out and applying pressure
Circuit breaker CB6 OK.
to side of gage, adjust for proper
Wire 1 OK.
fit for ground.
Run relay OK.
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
Blackout light switch OK.
Wire 13 OK.
Connector J1 OK.
Connector P1 OK.
POSSIBLE PROBLEMS
Adjust grounding
NO
fins (Para 8-6).
Socket(s) faulty.
Faulty Ground
YES
Replace bulb
(Para 8-6).
15
KNOWN INFO
TEST OPTIONS
Bulb(s) OK.
Continuity Test.
Is continuity present on wire 9
Connector P2 OK.
STE/ICE-R #88
between starter motor
Connector J2 OK.
REASON FOR QUESTION
Circuit breaker CB6 OK.
solenoid and connector P2-1?
If continuity is not present, wire 9
Wire 1 OK.
or connector P2 are faulty.
Run relay OK.
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
Blackout light switch OK.
Wire 13 OK.
Socket(s) OK.
POSSIBLE PROBLEMS
Fautly Wire 9
Repair wire 9 or
Faulty Connector J2
NO
connector P2
Faulty Connector P2
(Para 8-49).
YES