TM 10-3930-660-24-2
BOOM ELECTRICAL CABLE REPLACEMENT - CONTINUED
0233 00
INSTALLATION - CONTINUED
11.
Connect four electrical leads (5) at autoleveler circuit
3
board (4) as tagged.
12.
Install cover (2) to electrical box (3) with four screws
5
(1).
7,8
10
409-421A
1
4
2
NOTE
Install clamp assembly closest to hose tensioner first.
13.
Have assistant pull boom cable snug, but not tight,
from rear of hose tensioner (21).
14.
Have assistant continue to hold cable (12) snug.
15.
Secure cable (12) to underside of outer boom with
12
25
cable clamp halves (25), cover plates (24), new lock-
washers (23) and capscrews (22).
25
23
24
22
409-425
16.
Adjust tension of cable (12) at tensioner (21).
21
36
17.
Adjust two capscrews (19) until length of compressed
spring (36) is 2 1/4 - 2 1/2 in. (57.15-63.5 mm) long.
18.
Tighten two jamnuts (19) after adjusting two cap-
screws (20).
19
20
12
409-1732