19.
Install new tie strap (34) to end of sleeve (35) inside
boom.
20.
Install clamp halves (33), cable guide bracket (32),
29
two new lockwashers (31) and two capscrews (30) to
secure cable (12) to boom.
12
21.
Plug boom electrical cable (12) into connector (29).
22.
Check for proper installation of boom electrical cable
33
(12).
23.
Connect batteries (WP 0107 00).
31
33
30
32
24.
Start engine.
35
34
12
25.
Test all boom and attachment functions to ensure
proper cable installation.
409-428
26.
Check that cable and hoses track properly in the boom.
27.
Check boom hose and cable tension and adjust, if necessary.
28.
Position cover (28) on rear of outer boom and secure
with four new lockwashers (27) and four capscrews
(26).
28
26 27
409-426
29.
Install load backrest to MLRS attachment, if removed (TM 10-3930-660-10).
30.
Operate boom and check for proper operation (TM 10-3930-660-10).
END OF WORK PACKAGE