TM 10-3930-660-24-2
BOOM ELECTRICAL CABLE REPLACEMENT - CONTINUED
0233 00
INSTALLATION - CONTINUED
NOTE
Guide cable over pulley at rear of boom before pulling cable tight in step 3. Be sure cable is properly
positioned in sheave of pulley.
Be sure cable is positioned through sleeve inside boom during step 3.
3.
Have an assistant feed cable (12) through hole at rear of boom. Carefully pull rope at front of boom until cable (12)
appears.
4.
Untie rope at front of boom from cable (12) and
MLRS attachment.
5.
Secure clamp (18) and cable (12) to underside of
MLRS attachment with flatwasher (17), new lock-
washer (16) and nut (15).
12
18
17
15
16
409-423
6.
Carefully pull cable through grommet (14) and into
12
9,10,11
electrical box (3).
13
14
7.
Secure electrical cable (12) to electrical box (3) with
two new tie straps (13).
8.
Connect boom cable leads (9) to boom electrical box
3
(3), as tagged.
9.
Place electrical leads (9), as tagged, on terminal strips
(10) inside electrical box (3).
409-422
10.
Tighten screws (11) on terminal strips (10) to secure
leads (9).
0233 00-5
|