20.
Tie other end of rope to MLRS attachment to prevent rope from being pulled entirely through boom during cable
removal.
21.
Remove electrical cable (12) from inside boom.
21
22.
Carefully pull cable (12) at rear of boom until rope
appears.
23.
Carefully pull cable (12) through access hole at hose
tensioner (21) until rope appears.
24.
Untie rope end from cable (12) and tie rope end to
hose tensioner assembly (21).
ACCESS HOLE
12
409-1732A
INSTALLATION
1.
Untie rope end from hose tensioner (21) and tie rope
end to electrical cable (12). Cover knot area with elec-
trical tape to prevent knot from snagging side boom.
12
409-430
2.
Have an assistant feed cable (12) through access hole at hose tensioner (21). Pull rope from rear of boom until cable
appears.