TM 10-3930-660-24-1
HYDRAULIC OIL SIGHT GAUGES REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Vehicle parked on level ground (TM 10-3930-660-
Tool kit, general mechanic's (Item 39, WP 0324 00)
10)
Materials/Parts
Hydraulic tank drained below level of lower sight
gauge (WP 0032 00)
Sealant, Loctite (Item 48, WP 0323 00)
NOTE
To prevent spillage of hydraulic oil, the hydraulic tank must be partially drained until the hydraulic oil level
is lower than the sight gauge being replaced (WP 0032 00).
REMOVAL
Remove sight gauges (1) from side of hydraulic tank
(2).
INSTALLATION
NOTE
Apply loctite to sight gauges as installed.
1.
Install two sight gauges (1) into side of hydraulic tank
(2).
2.
Fill hydraulic tank (2) (WP 0032 00).
1
2
409-794
END OF WORK PACKAGE
|