Click here to make tpub.com your Home Page

Page Title: HYDRAULIC BYPASS SWITCH MAINTENANCE
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-3930-660-24-1
HYDRAULIC BYPASS SWITCH MAINTENANCE
THIS WORK PACKAGE COVERS
Removal, Installation, Testing
INITIAL SETUP
Personnel Required
Tools and Special Tools
Two
Shop equipment, common no. 1 (Item 20, WP 0324
Equipment Condition
Materials/Parts
Vehicle parked on level ground (TM 10-3930-660-
10)
Cap and plug set (Item 8, WP 0323 00)
Sealant, Loctite (Item 44, WP 0323 00)
Rag, wiping (Item 40, WP 0323 00)
Tag, marker (Item 57, WP 0323 00)
WARNING
Do NOT remove hydraulic tank filler cap or disconnect or remove any hydraulic system line or fitting
unless hydraulic system pressure has been relieved. Hydraulic system pressure can be over 3,000 psi
(20685 kPa), even with engine and pump OFF. To relieve pressure, lower all hydraulic attachments to
the ground and shut down engine. Move control levers through all operating positions, then SLOWLY
loosen hydraulic tank filler cap. After maintenance, tighten all connections before applying pressure.
Escaping hydraulic fluid under pressure can penetrate the skin, causing injury or death.
At operating temperature hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulics. Failure to do so could result in injury.
CAUTION
Wipe the area clean around all hydraulic connections to be opened during removal and disassembly. Cap
lines and plug holes after removing lines. Contamination of the hydraulic system could result in premature
failure.