CIRCUIT BREAKERS REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Vehicle parked on level ground (TM 10-3930-660-
Tool kit, general mechanic's (Item 39, WP 0324 00)
10)
Materials/Parts
Battery cables disconnected (WP 0107 00)
Sealant, Loctite (Item 44, WP 0323 00)
Lockwasher (5 and 11)
REMOVAL
NOTE
The circuit breakers are reached through the access hole at the base of the operator console.
All ten circuit breakers are installed and removed in the same manner.
The circuit breakers protect the entire electrical system except for the power circuit to the emergency steer
pump.
The circuit breakers will trip if there is a shorted or grounded wire.
The circuit breakers will automatically reset after cooling. They cannot be reset manually.
Under normal operating conditions, circuit breakers should never require replacement. However, if a circuit
breaker does not reset after it has cooled, the circuit breaker is defective and must be replaced.
1.
Remove four capscrews (1) and access cover (2) at
base of operator console (3).
1
2
3
409-278
|