TM 10-3930-660-24-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 7. MLRS Attachment Group Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c. Under normal operating
3.
Fork Auto Leveling and Electric Joystick
conditions, circuit
Does Not Work - Continued.
breakers should never
require replacement.
However, if a circuit
breaker does not reset
after it has cooled, the
circuit breaker is
defective and must be
replaced (WP 0071 00).
1. Check for defective
Check electrical joystick
4.
MLRS Attachment Hoist/Lower Function
electrical joystick assembly.
Does Not Work.
assembly and replace if
defective (WP 0078 00).
2. Check for bad ground or
Inspect wires and connections
loose connections.
|