TM 10-3930-660-24-1
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 4. Lighting System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check if circuit breaker (CB
Check backup alarm circuit for
5.
Backup Alarm Does Not Sound.
2) is tripped.
shorts, broken wire, or bad
ground. Refer to Electrical
a. The circuit breakers will
trip if there is a shorted or
grounded wire.
b. The circuit breaker will
automatically reset after
cooling. They cannot be
reset manually.
c. Under normal operating
conditions, circuit
breakers should never
require replacement.
However, if a circuit
breaker does not reset
after it has cooled, the
circuit breaker is
defective and must be
replaced (WP 0071 00).
2. Check for defective backup
Check switch and switch wires
alarm switch, broken switch
for continuity (WP 0109 00).
wires, or loose connections.
3. Check for defective backup
Test backup alarm. Replace if
alarm.
defective (WP 0103 00).
4. Check for defective blackout
Replace switch if defective (WP
light switch.
5. Check for bad or weak cell in
Test battery using hydrometer
battery.
(TM 9-6140-200-14).
|