Table 1. Charging System Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Check for loose or corroded
Clean and tighten battery
1.
Alternator Not Charging or Insufficient
battery connections.
Charging.
connections as needed (WP
2. Check for alternator belt
slippage.
a. Check belt tension and
replace belt if required
b. Check belt tensioner
operation, and replace belt
tensioner if necessary
BELT TENSIONER
DRIVE BELT TENSION:
1/2 IN. (13 mm) DEFLECTION
IN LONGEST SPAN OF BELT
409-116
3. Check for alternator pulley
Check pulley nut torque and
loose on shaft.
torque to 70-80 ft-lb (95-108
Nm) if necessary (WP 0062 00).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |