TM 10-3930-638-24&P
4-5. AXLE MAINTENANCE (cont)
b. Differential Case and Gear Assembly (cont).
REMARKS
ACTION
ITEM
LOCATION
STEP
CLEANING
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
4
Bearings (17 and
Clean
Use cleaning solvent P-D-680; soak in clean-
18)
ing solvent then remove and strike flat
of bearing against block of wood to
dislodge solidified lubricant particles.
Dry with clean, soft, lintless absorbent
cloths. Don't use compressed air to dry
5
Clean
Use cleaning solvent P-D-680. Dry with
All other parts
clean cloths
6
Inspect
Ring gear (16), side
Inspect for wear, damage, cracks, pits and
gear (6 and 10),
scoring. Inspect gear teeth for wear,
cracks and damage. If any of these con-
and pinion gears (8)
ditions are observed replace part
NOTE
Ring gear (16) and pinion shaft (paragraph 4-5a, key number 19)
shall be replaced as a matched set. Pinion gear (8) and side gear (6
and 10) shall be replaced as a set.
7
Inspect
Case halves (3 and 4),
Inspect for wear, cracks, pits, scoring,
spider (9), and thrust
damage and distortion. If any of these
conditions are observed, replace part
washers (5, 7, and 11)
NOTE
Replace thrust washers (5 and 11) and thrust washer (7) in sets;
combination of old and new thrust washers will result in premature
failure.
4-249
|