TM 10-3930-636-24&P
3-13. STARTER AND SOLENOID REPAIR (cont)
ITEM
ACTION
LOCATION
REMARKS
STEP
DISASSEMBLY (cont)
h. Four screws (43)
Remove
i. Four nuts (44)
Remove
(cont)
j. Four lock washers
Remove and
discard
(45)
k. Two control assem-
Remove
blies (46)
NOTE
Do not remove screw (47), lock washer (48), connector (2) or
grommet (49) unless replacement is required.
l. Screw (47)
Remove
m. Lock washer (48)
Remove
Remove
n. Connector (2)
o. Grommet (49)
Remove
NOTE
Do not remove field coil assembly (52), pole shoes (51) or screws
(50) unless parts need replacement.
p. Eight screws (50)
Remove
q. Four pole shoes (51)
Remove
r. Field coil assembly
Remove and
release
(52)
CLEANING
Wipe with a clean, dry, lint-free cloth only.
6
Armature (10), drive
Clean
Do not use cleaning solvent
assembly' 15), solenoid
switch (24), brushes
(39), grommet (49)
and coil assembly (52)
WARNING
Dry cleaning solvent (P-D-680), used to clean parts is toxic and
flammable. Wear protective goggles and gloves and use only in a
well ventilated area. Avoid contact with skin, eyes, and clothes
and don't breathe vapors. Do not use near open flame or exces-
sive heat and don't smoke when using it. Failure to do so could
cause serious injury. If you become dizzy while using cleaning
solvent, get fresh air immediately, and get medical attention. If
contact with skin or clothes is made, flush with large amounts of
water. If contact with eyes is made, wash eyes with water immedi-
ately, and obtain medical aid immediately.
3-106
|