TA031862
b. Removal. The neutral start switch is located on
4-38. Neutral Start Switch
the transmission control valve. Refer to figure 4-24 and
a. Testing. To test the neutral start switch, connect a
remove the neutral start switch.
test light between the switch terminals. Place the for-
C. Cleaning and Inspection.
ward-neutral-reverse control lever in the neutral posi-
(1) Clean the neutral start switch with an ap-
tion. The test light should light. If not, place the valve
proved cleaning solvent.
plunger in the neutral position by hand. If the test light
(2) Inspect the switch for corrosion. Check wiring
lights, then the problem is in the valve control linkage.
for cuts and deterioration. Replace a defective switch.
d. Installation. Refer to figure 4-24 and install the
If the test light does not light, then the neutral start
neutral start switch.
switch is defective.