TM 10-3930-634-12
TA031857
and Cables.
WARNING
Always disconnect battery ground cable first.
a. Removal.
(1) Disconnect battery ground cable. Then, refer to
jumper cables as shown.
(2) Remove four wing nuts and lift out the battery
holddown cover.
(8) Lift out two batteries.
b. Cleaning and Inspection.
(1) Clean the battery holddown cover, batteries
and cables.
(2) Inspect the cover for cracks and breaks. Check
batteries for corrosion and electrolyte level. Inspect ca-
bles for security and corrosion. Replace defective parts.
Refer to TM 9-6140-200-15 for maintenance of bat-
teries.
c. Painting. Paint the battery areas as necessary
with an acid resistant paint to prevent corrosion.
d. Installation.
(1) Install two batteries in case.
(2) Use four wing nuts to reinstall battery hold-
down cover.
(3) Refer to figure 4-20 and reconnect the positive,
negative, and jumper cables as shown. Reconnect bat-
tery ground cable.
CAUTION
This is a negative ground system. To
reverse polarity will damage the voltage
TA031858
regulator. Be sure all battery connection
are clean and secure.
|