Section XI. INSTRUMENT PANEL AND INSTRUMENTS
4-22. Instrument Panel
leads from the controls and instruments on
a. Removal and Disassembly.
the instrument panel.
CAUTION
(1) Remove the assembled instrument
panel from the lift truck as shown in figure 4-5.
Disconnect the positive battery cable from
the battery before disconnecting electrical
Figure 4-5. Instrument Panel, Disassembly and Reassembly
(2) Tag all leads before disconnecting the:
(1) Clean the meters, gages, and switches
m to assure that they are identified for reassemble y.
with a cloth dampened with dry cleaning solvent P-D-
(3) Disassemble the instrument panel as
680. Take care to prevent solvent from entering the
required, as shown in figure 4-5.
parts.
WARNING
(2) Clean all other parts with dry cleaning
solvent P-D-680; dry thoroughly.
Dry cleaning solvent, P-D-680, used to
(3) Inspect meters and gages for cracked
clean parts is potentially dangerous to
glass, illegible dial faces, damaged terminals, faulty
personnel and property. Avoid repeated
movements, and other damage.
and prolonged skin contact. Do not use
(4) Inspect switches for rough, catching, or
near open flame or excessive heat. Flash
binding operation, damaged terminals, signs of
point of solvent is 100F. -138F. (38C. -
60C.).
b. Cleaning and Inspection.
4-20
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |