ME 3930-624-34/5-1
1. Thru bolts
24. Nut
2. Shaft nut
25. Lockwasher
3. Washer
26. Washer
4. Pulley
27. Insulating washer
5. Fan
28. Insulator
29. Terminal stud
6. Collar
30. Capscrew
7. Key
31. Washer
8. Rotor
9. Capscrew
32. Brush holder
33. Brush
10. Retainer
34. Brush spring
11. Collar
35. Capscrew
12. Gasket
36. Lockwasher
13. Bearing
37. Washer
14. End frame
38. Capacitor
15. Stator
39. Nut
16. End frame bearing
40. Lockwasher
17. Retainer
41. Terminal stud
18. Nut
42. Insulator
19. Lockwasher
43. Diode (positive)
20. Washer
44. Diode (negative)
21. Insulating washer
45. Heat sink
22. Insulating washer
46. Frame
23. Terminal stud
Figure 5-1. Alternator.
c. Cleaning, Inspection and Repair.
(a) Check the rotor circuit for grounds.
(1) Cleaning. Clean all parts of the alternator
Connect a test lamp or an ohmmeter to each of the
with cleaning solvent, except for the stator (15, fig.
slip rings in turn and to the rotor shaft. Refer to fig.
5-2. If the lamp lights or the ohmmeter produces a
with compressed air.
low reading, it indicates that the rotor is grounded
(2) Rotor checking procedure.
and the alternator must be replaced.
5-2
|