 |  TM 10-3930-621-34 f. Mounting Plate. (1) Place wooden block across vise throat to support spool parts. (2) Clamp control assembly (38) across port face with control end up and remove mounting plate attaching bolts (18). (3) Hold spool assembly down against wooden block and lift off mounting plate (17). (4) Inspect  mating  surfaces  for  obvious leakage path ard wear. Remove and discard quad ring shaft seal (24) and oil seal (16) in mounting plate (17). g. Control Assembly. (1) Remove cap locator bushing (39), and packing (40). Discard packing. (2) Place port face of housing (48) on a solid surface and remove control spool and sleeve from 14- hole end of housing. Caution: Use extreme care when removing control spool and sleeve, as they are very closely fitted and must be rotated slightly as they are withdrawn. (3) Using a small bent tool or wire, remove check valve seal plug (44) from housing (48) by reaching it through "out" port and pushing up- wards. See figure Figure 9-3. Removing check valve seal plug 9-3. Remove and discard packing (43). Caution: Do not pry against edge of hole in housing bore. 9-4 | 