f. Mounting Plate.
(1) Place wooden block across vise throat to
support spool parts.
(2) Clamp control assembly (38) across port face
with control end up and remove mounting plate attaching
bolts (18).
(3) Hold spool assembly down against wooden
block and lift off mounting plate (17).
(4) Inspect mating surfaces for obvious
leakage path ard wear. Remove and discard quad ring
shaft seal (24) and oil seal (16) in mounting plate (17).
g. Control Assembly.
(1) Remove cap locator bushing (39), and
packing (40). Discard packing.
(2) Place port face of housing (48) on a solid
surface and remove control spool and sleeve from 14-
hole end of housing.
Caution: Use extreme care when removing
control spool and sleeve, as they are very closely
fitted and must be rotated slightly as they are
withdrawn.
(3) Using a small bent tool or wire, remove
check valve seal plug (44) from housing (48) by reaching
it through "out" port and pushing up- wards. See figure
Figure 9-3. Removing check valve seal plug
9-3. Remove and discard packing (43).
Caution: Do not pry against edge of hole in
housing bore.