Repeat steps above until drop-out is
6-244. FIELD WEAKENING ADJUSTMENT.
correct.
a.  Field weakening provides for maximum truck
speed and is controlled through the shorting contactor
(6)  Again accelerate until the SC and FW
SC relay (17, figure 7-3).
relays close and gently apply brake until FW relay drops
out.
b.  Field weakening relay is adjusted to operate at
the following amperes:
(7)  Gradually release brake until the FW relay
picks up and note current draw on ammeter.
(1)
Relay
closes
(pick-up)
125
to
150
amperes.
(8)  If not 125 to 150 amperes, release both
brake and accelerator.
(2)
Relay opens (drops out) 350 to 365
amperes.
(9)  Adjust  field  weakening  pack  pick-up
trimmer (figure 6-2) similar to (4) above.
c.
Adjust or pick-up and drop-out as follows:
CAUTION
(1)  With direction control in forward direction,
depress accelerator pedal slowly until two clicks of the
Avoid excessive operation of loading motor by
shorting contactor SC (17) and the field weakening FW
applying service brakes with the brake switch
(19) relays are heard or the contacts are seen to close.
jumped.  This will cause extreme motor heat
Hold this accelerator position.
and excessive wear of brake lining.
(2)  Gently apply fool service brake while
6-245. CURRENT LIMIT ADJUSTMENT.
holding motor speed until the field weakening relay
a.  The current limit prevents excess current from
drops out. Note current draw on ammeter.
damaging the system. The limit must be adjusted when
changing from a lead-acid to a nickel-iron alkaline
(3)  If not 350 to 365 amperes, release both
battery. See para 6251.
brake and accelerator.
b.  The current limit must be adjusted to a
(4)  Adjust field weakening pack (20) drop-out
maximum of 200 amperes.
trimmer (figure (-2). Loosen locknut and turn clockwise
to decrease current draw. Lock locknut.
Figure 6-2. Electrical Control Trimmer Locations
6-50