TM 10-3930-609-35
Do not use wire or metallic rod or
e. Take out spring retaining screws, spring
pick to clean fluid passages since
retainers, springs and washers.
such procedure could result in
f. Remove plungers from valve body.
irreparable damage to parts.
g. Remove packings and remaining plugs from
valve body.
3-56. Inspection of Control Valve Parts
a. Inspect Valve body for cracks and for scoring or
3-55. Cleaning Parts of Control Valve
other damage to plunger bores.
a. Wash parts thoroughly in SD. Dry parts with
b. Inspect threaded parts and tapped holes for
soft lintfree cloth or with compressed air under moderate
stripping or other damage to threads.
pressure.
c. Carefully inspect plungers for surface defects
b. Assure that all fluid passages are free of
such as scoring, pitting or excessive wear.
obstructions.
d. Inspect poppet and bearing for wear and
scoring.
Caution
Figure 3-11. Control valve, sectional view.
3-19
|