TM 10-3930-242-12
Table 4-1. Organizational Preventive Maintenance Checks and Services-Continued
Q Quarterly
A-Annually
Interval
Item To Be Inspected
Item
Procedure: Check for and have repaired, filled, or adjusted as needed.
Q
A
No.
4
WARNING
Low pressure air used for cleaning purposes will not exceed 30 psi. Effec-
tive chip guarding and personnel protective equipment (goggles/shield,
gloves, etc.) will be used.
If NBC exposure is suspected, all air filter media will be handled by per-
sonnel wearing full NBC protective equipment.
Clean air cleaner filter with low pressure air by blowing from the inside out
5
b. Replace secondary fuel filter (para 4-22).
6
CRANKCASE BREATHER
Clean crankcase breather (para 4-13).
7
SERVICE BRAKES
Check for lining wear (para 4-59).
8
HOSES, LINES, AND FITTINGS
Inspect all hoses, lines, and fittings for damage or leaks (para 4-77).
PARKING BRAKE
9
Check parking brake for proper adjustment (para 4-60 and 4-61).
10
FRAME AND CARRIAGE
Check frame, forks, and carriages for damage, cracks, or bends.
RADIATOR
11
WARNING
Pressurized cooling system. Remove cap slowly and only when radiator is
cool or serious burns could result.
Check coolant condition in accordance with TB 750-651 and inspect cooling system
for excessive rust or corrosion. Drain, clean, and refill the cooling system if required
(para 4-25 and 4-26).
Change 2
4-3.0/(4-3.1 blank)
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |