TM10-3930-242-12
Section IV. OPERATOR/CREW MAINTENANCE PROCEDURES
Loosen the clamp and remove the cup. Remove the
element and inspect it for excessive accumulation of
dirt. Remove the cup dust trap and inspect for
WARNING
If NBC exposure is suspected, all air filter me-
excessive accumulation of dust. Report to
dia should be handled by personnel wearing
organizational maintenance for Servicing.
protective equipment. Consult your unit NBC
Officer or NBC NCO for appropriate handling
or disposal procedures.
Refer to figure 3-2 and service the ether primer.
3-8. Battery
electrolyte. The electrolyte should be one-half inch
Visually inspect batteries for damage, such as loose
above the plates. Replace vent cap. Inspect cables
and battery holddown hardware for corrosion.
terminal posts or warped internal plates. Remove
battery cell vent caps (fig. 3-3) and check the level of
Change 3
|