TM 10-3930-222-20
(4) Remove the capscrews (15) and lockwashers
(2) When a denatured alcohol and water solution is
(14) that secure the fan to the hub and remove
used as emergency antifreeze protection, add 1
the fan.
ounce of corrosion inhibitor to each 2 quarts of
water used in the solution.
(5) Disconnect and remove the water hose at the
pump.
37. Fan and Generator V-BeIt
(6) Unscrew the screws (2) and lockwashers (3) that
secure the pump to engine and remove the
a. Adjustment and Inspection. Raise the hood and
pump.
inspect the V-belt for wear, frays, and proper tension,
(7) Using a suitable puller, remove the hub (12)
and adjust for 1/2-inch finger pressure deflection at
from the water pump.
midpoint between generator and fan pulleys. Refer to
b. Installation. Reverse procedures in a above.
figure 32 and remove the V-belt as follows:
39. Thermostat
b. Removal.
(1) Loosen the bolt and lockwasher that secure the
a.
Removal.
generator to the generator adjusting plate.
(1)
Drain the cooling system.
Move the generator toward the engine and
(2)
Remove the top radiator hose.
remove the fan and generator V-belt from the
(3)
Disconnect the thermostat by-pass line.
generator.
(4)
Remove the mounting nuts and lockwashers
(2) Remove  the  capscrews  that  secure  the
and remove the thermostat housing and gasket.
hydraulic pump drive flange yoke to the
(5) Remove the thermostat from cylinder head.
crankshaft pulley and move the flange yoke
from the pulley.
(3) Remove the V-belt from the pulley.
b. Installation. Reverse procedures in a above.
c. Testing.
c. installation.
Reverse procedures in b and a
(1) Place the thermostat in a suitable container of
above.
water.
(2) Heat the water.
38. Water Pump and Fan
(3) Use a thermometer to determine at what degree
a. Removal.
thermostat operates.
(1) Open the drain valve at bottom of radiator and
(4) A properly operating thermostat will begin to
drain the radiator.
open at 160F. and will be fully opened at 1800
F.
(2) Disconnect the water recirculating tube (7, fig.
33) at pump body (4).
(5) If the thermostat does not operate properly,
discard it.
(3) Remove the fan belt (par. 37).
74