20-3. ARCTIC HEATER FUEL PUMP REPLACEMENT
This Task Covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts
Tools and Special Tools
Container, 1 gal. (3.81) capacity
Tool Kit, General Mechanic's: Automotive
Locknut
(Item 18, Appendix F)
Equipment Condition
Negative battery cable disconnected (Para 8-44)
a. Removal.
WARNING
Do not smoke or allow open flame or
sparks in the vicinity while working on
any part of fuel system. Diesel fuel is
highly flammable and can cause injury or
death to personnel if accidentally ignited.
(1)
Disconnect connector (1) of heater wiring
harness (2) from connector of fuel pump (3).
NOTE
Clamp fuel hose closed to prevent fuel
loss when hose is disconnected.
TR00883
(2)
Loosen clamp (4) and disconnect fuel
pressure hose (5) from top of fuel pump (3).