TM 10-3930-673-20-2
17
This Task Covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts
Tools and Special Tools
Compound, Sealing (Item 32, Appendix C)
Tool Kit, General Mechanic's: Automotive
Preformed Packings (2)
(Item 18, Appendix F)
Equipment Condition
Hydraulic tank drained below level of sight gage (Para
a. Removal.
NOTE
To prevent spilling of hydraulic oil,
hydraulic tank must be partially drained
until oil level is lower than sight gage
being replaced (refer to Para 5-9).
TR00003
Remove two screws (1), preformed packings (2),
and sight gage (3) from hydraulic tank (4).
Discard preformed packings.
4
b. Installation.
3
2
(1)
Apply sealing compound to threads of two
1
screws (1).
(2)
Install sight gage (3) on hydraulic tank (4)
with two preformed packings (2) and
screws (1). Tighten screws to 4 - 5 lb-ft (5.4 -
6.7 Nm).
TR00846
NOTE
Follow-on Maintenance: Fill hydraulic tank (2)
END OF TASK
|