TM 10-3930-673-20-2
(b)
Remove sampling valve (7) from elbow
(8).
(c)
Remove tube (9) from elbow (8) and tee
(10).
(d)
Remove elbow (8) and preformed
packing (11) from filter base (2). Discard
preformed packing.
(e)
Remove four screws (12), lockwashers
(13), washers (14), spacer (15), and filter
base (2) from bulkhead (3). Discard
lockwashers.
b. Installation.
(1)
Install filter base (2) on bulkhead (3).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
TR00698
and clothing. To avoid injury or death,
keep away from open fire and use in a
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(a)
Apply sealing compound to threads of four screws (12).
(b)
Install spacer (15) and filter base (2) on bulkhead (3) with four washers (14), lockwashers (13), and
screws (12).
(c)
Install preformed packing (11) and elbow (8) in filter base (2).
(d)
Apply sealing compound to threads of tube (9) and install on tee (10) and elbow (8).
(e)
Apply sealing compound to threads of sampling valve (7) and install in elbow (8).
|