TM 10-3930-673-20-2
TR00683
(2)
Connect hydraulic hose (4) on main control valve (5).
(3)
Connect two hydraulic hoses (1 and 2) on boom cylinder flow control valve (3).
(4)
Install transmission cover (Para 16-5)
NOTE
It is possible that hydraulic pumps have air in pump cavities. Air must be purged from cavity before
pump will operate.
(5)
Purge boom hydraulic circuit.
(a)
Start engine (TM 10-3930-673-10).
(b)
Purge air from hydraulic circuit by raising and lowering boom five times.
(c)
Stop engine and relieve hydraulic pressure by operating boom raise and lower controls (TM 10-3930-673-
10).
END OF TASK