TM 10-3930-673-20-2
8-50. BOOM ELECTRICAL CABLE TEST/REPAIR/REPLACE (CONT)
CAUTION
Support cover as required so that weight
of cover and circuit board is not supported
by electrical wires to board, or damage to
equipment could result.
TR00004
(3)
Loosen four screws (1) and separate cover (2)
from boom electrical box (3).
(4)
Tag, mark, and disconnect three electrical
wires (4) from terminal strip (5) of
autoleveler circuit board (6).
(a)
Tag and mark three electrical wires (4) on
terminal strip (5) of autoleveler circuit
board (6).
(b)
Loosen three screws (7) and remove
electrical wires (4).
TR00372
(5)
Tag, mark, and disconnect 13 boom cable
electrical wires (8) on two terminal strips (9
and 10) of boom electrical box (3).
(a)
Tag and mark 13 boom cable electrical
wires (8) on two terminal strips (9 and 10)
in boom electrical box (3).
(b)
Loosen 13 screws (11) on two terminal
strips (9 and 10) and remove 13 boom
cable electrical wires (8).
TR00373
NOTE
Remove tie wraps as necessary.
(6)
Tag, mark, and remove boom electrical cable (12) from boom electrical box (3).
|