TM 10-3930-673-20-2
8-43. AUXILIARY BATTERIES SERVICE/TEST/REPLACEMENT (CONT)
(3)
If necessary, add distilled water to cells of
13
auxiliary batteries (4 and 5).
(a)
Remove 12 fill plugs (13) from auxiliary
batteries (4 and 5).
(b)
Fill each cell to top of ledge in filler neck
with distilled water.
(c)
Install fill plugs (13).
4
2
5
TR00751
(4)
Install auxiliary battery box cover (1) on
auxiliary battery box (2).
3
Position auxiliary battery box cover (1) on
auxiliary battery box (2) and hook two rubber
hooks (3).
c. Removal.
1
(1)
Remove auxiliary battery box cover (1) from
auxiliary battery box (2) as described in
step b. Service.
2
TR00749