TM 10-3930-673-20-2
8-42. BATTERIES SERVICE/TEST/REPLACEMENT (CONT)
(2)
Remove battery cables (6 through 8) from
21
20
battery terminals (9 through 12).
22
20
(a)
Loosen nut (14) and screw (15) and
8
21
15
22
remove clamp (16) and negative battery
16
6
cable (6) from negative terminal (9) of
7
14
19
right-hand battery (4).
17
18
11
(b)
Loosen nut (17) and screw (18) and
12
9
remove clamp (19) and positive battery
cable (7) from positive battery terminal
(12) of left-hand battery (5).
(c)
Loosen two nuts (20) and screws (21) and
remove two clamps (22) and crossover
battery cable (8) from positive terminal
(11) of right-hand battery (4), and
10
negative terminal (10) of left-hand battery
(5).
4
5
TR00759
(3)
Remove three locknuts (23), washers (24),
23
retaining screws (25), and battery retaining
bar (26) from battery box (2). Discard
24
locknuts.
26
(4)
Note position and remove left-hand battery
(5) and right-hand battery (4) from battery
box (2).
d. Installation.
(1)
Position left-hand battery (5) and right-hand
battery (4) in battery box (2).
(2)
Install battery retaining bar (26) across
batteries (4 and 5) with three retaining
screws (25), washers (24), and locknuts
(23).
4
5
25
2
TR01778
8-116
|