(3)
If necessary, add distilled water to cells of
13
batteries (4 and 5).
(a)
Remove 12 fill plugs (13) from batteries
(4 and 5).
(b)
Fill each cell to top of ledge in filler neck
with distilled water.
(c)
Install fill plugs (13).
4
5
TR00758
(4)
Install battery box cover (1) on battery box
(2).
3
Position battery box cover (1) on battery box (2)
and hook two rubber hooks (3).
c. Removal.
1
(1)
Remove battery box cover (1) from battery
box (2) as described in step b. Service.
2
TR00755