TM 10-3930-673-20-2
8-25. BOOM ELECTRICAL JUNCTION BOX ASSEMBLY REPLACEMENT (CONT)
(4)
Remove four nuts (9), lockwashers (10), and
10
9
11
boom electrical junction box (4) from
studs (11) on boom (12). Discard
lockwashers.
b. Installation.
4
(1)
Install boom electrical junction box (4) on
studs (11) with four lockwashers (10) and
nuts (9).
12
TR00342
NOTE
Install tie wraps as necessary.
4
(2)
Connect eight electrical cables (8) on boom
electrical junction box (4).
(3)
Install boom electrical cable (7) in boom
8
electrical junction box (4).
7
TR00341
(4)
Connect 28 electrical wires (1) on two
terminal strips (2 and 3) of boom electrical
2
6
3
junction box (4).
(a)
Position 28 electrical wires (1) on two
terminal strips (2 and 3) in boom
1
electrical junction box (4) and tighten
screws (5) on terminal strips (2 and 3).
5
(b)
Position electrical wire (1) on boom
electrical junction box (4) and install
1
screw (6).
NOTE
Follow-on Maintenance:
4
Install fork autoleveler switch
Connect negative battery cable
END OF TASK
8-76
|