TM 10-3930-673-20-2
3
This Task Covers:
Electrical Testing of Shut-off Solenoid
INITIAL SETUP
Personnel Required
Tools and Special Tools
Two
Tool Kit, General Mechanic's: Automotive
(Item 18, Appendix F)
References
TM 10-3930-673-10
Test Equipment
Multimeter (Item 9, Appendix F)
Electrical Testing of Shut-off Solenoid.
WARNING
Do not smoke or allow open flame or
sparks in the vicinity while working on
TR00003
any part of fuel system. Diesel fuel is
highly flammable and can cause injury or
death to personnel if accidentally ignited.
NOTE
If fuel shut-off solenoid replacement is
required, notify Direct Support
Maintenance.
Ensure starter keyswitch is in the OFF
position during Step (1) below.
1
(1)
Test resistance of fuel shut-off solenoid (1).
4
(a)
Disconnect fuel shut-off solenoid
3
connector (2) from main wiring harness
(3).
2
6
5
NOTE
TR00346
Multimeter resistance should read 41.3 ohms
2.5 ohms during test in Step (1)(b). If reading
is not within acceptable limits, solenoid requires
replacement. Notify Direct Support Maintenance.
(b)
Place one probe of multimeter on red wire terminal (4) of fuel shut-off solenoid connector (2). Place other
probe on black wire terminal (5) of fuel shut-off solenoid connector.
|