TM 10-3930-673-20-1
38. TEMPERATURE GAGE DOES NOT OPERATE (CONT).
5
KNOWN INFO
TEST OPTIONS
No temperature reading.
Continuity test.
Is continuity present on
Wire 9 OK.
STE/ICE-R #91.
wire 15 between temp gage
Connector P2 OK.
REASON FOR QUESTION
and connector J1-10?
Connector J2 OK.
If continuity is not present, wire 15
Circuit breaker CB6 OK.
or connector J1 faulty.
Wire 1 OK.
Run relay OK.
Wire 3 OK.
Circuit breaker CB1 OK.
Wire 10 OK.
Temperature gage OK.
POSSIBLE PROBLEMS
Wire 15 faulty.
Repair wire 15
Connector J1 faulty.
(Para 8-48) or
NO
Connector P1 faulty.
connector J1
(Para 8-48).
YES
6
KNOWN INFO
TEST OPTIONS
No temperature reading.
Continuity test.
Is continuity present on
Wire 9 OK.
STE/ICE-R #91.
wire 15 between water temp
Connector P2 OK.
REASON FOR QUESTION
transducer and
Connector J2 OK.
If continuity is not present, wire 15
Circuit breaker CB6 OK.
connector P1-10?
or connector P1 faulty.
Wire 1 OK.
Run relay OK.
Wire 3 OK.
Circuit breaker CB1 OK.
Wire 10 OK.
Connector J1 OK.
POSSIBLE PROBLEMS
Connector P1 faulty.
Repair wire 15
Wire 15 faulty.
(Para 8-49) or
NO
connector P1
(Para 8-49).
YES
Replace engine
water temperature
transducer
(Para 8-36).
2-556
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |