TM 10-3930-673-20-1
P2-1
J2-1
CONTINUITY TEST
(1) Disconnect negative battery cable from
negative side of battery (Para 8-42).
(2) Disconnect connector J2 from
connector P2.
CONNECTOR
J
(3) Set multimeter to ohms.
2
(4) Connect multimeter positive lead (+) to
wire 9 where wire 9 connects to circuit
breaker CB6.
(5) Connect multimeter negative lead () to
CONNECTOR P2
connector J2-1.
(a) If continuity is present, go to Step 9
of this fault.
(b) If continuity is not present, repair
J
CONNECTOR
wire 9 or connector J2 (Para 8-48).
2
CONNECTOR P2
CONTINUITY TEST
STARTER SOLENOID
(1) Disconnect connector J2 from
connector P2.
(2) Set multimeter to ohms.
(3) Connect multimeter positive lead (+) to
WIRE 9
wire 9 where wire 9 connects to starter
motor solenoid.
(4) Connect multimeter negative lead () to
connector P2-1.
(a) If continuity is present, go to Step 3
of this fault.
(b) If continuity is not present, repair
wire 9 or connector P2 (Para 8-49).
WIRE 9
CIRCUIT BREAKER CB6
TR01551
2-517
|