TM 10-3930-673-20-1
34. NONE OF THE GAGES OPERATE (CONT).
8
KNOWN INFO
TEST OPTIONS
Gages do not operate.
Continuity test.
Is continuity present on wire 9
Battery OK.
STE/ICE-R #91.
between wire 9 and
Battery cable OK.
REASON FOR QUESTION
connector J2-1?
POSSIBLE PROBLEMS
If continuity is not present, wire 9
Wire 9 faulty.
or connector J2 faulty.
Connector P2 faulty.
Connector J2 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB1 faulty.
Wire 10 faulty.
Repair wire 9 or
NO
connector J2
(Para 8-48).
YES
9
KNOWN INFO
TEST OPTIONS
Gages do not operate.
Continuity test.
Is continuity present on wire 9
Battery OK.
STE/ICE-R #91.
between starter motor
Battery cable OK.
REASON FOR QUESTION
solenoid and connector P2-1?
Wire 9 OK.
If continuity is not present, wire 9
Connector J2 OK.
or connector P2 faulty.
POSSIBLE PROBLEMS
Connector P2 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run relay faulty.
Wire 3 faulty.
Circuit breaker CB1 faulty.
Wire 10 faulty.
Fuel gage faulty.
Repair wire 9 or
NO
Wire 12 faulty.
connector P2
Connector J1 faulty.
(Para 8-49).
Connector P1 faulty.
Fuel level transducer faulty.
YES
Go to Step 3 of this
fault.
2-516
|