TM 10-3930-673-20-1
19. BLACKOUT STOPLIGHTS DO NOT OPERATE (CONT).
17
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Continuity test.
Is continuity present between
Connector P2 OK.
STE/ICE-R #88.
blackout brake light socket
Connector J2 OK.
REASON FOR QUESTION
outside conductor ground
Wire 9 OK.
If continuity is not present, wire 2
Circuit breaker CB6 OK.
and ground cable?
ground or brake light socket
Wire 1 OK.
faulty.
Run relay OK.
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
Wire 41 OK.
Brake switch OK.
Blackout light switch OK.
Wire 42 OK.
Wire 44 OK.
Repair wire 2 (Para
NO
Connector J1 OK.
8-49).
Connector P1 OK.
POSSIBLE PROBLEMS
YES
Socket(s) faulty.
Ground faulty.
Replace bulb
(Para 8-33).
18
KNOWN INFO
TEST OPTIONS
Bulbs OK.
Continuity test.
Is continuity present between
Connector P2 OK.
STE/ICE-R #88.
starter motor solenoid and
Connector J2 OK.
REASON FOR QUESTION
connector P2-1?
Circuit breaker CB6 OK.
If continuity is not present, repair
Wire 1 OK.
wire 9 or connector P2
Run relay OK.
(Para 8-49).
Wire 3 OK.
Circuit breaker CB4 OK.
Wire 40 OK.
Wire 41 OK.
Brake switch OK.
Blackout light switch OK.
Wire 42 OK.
Wire 44 OK.
Repair wire 9 or
Connector J1 OK.
NO
connector P2
Connector P1 OK.
(Para 8-49).
Socket(s) OK.
POSSIBLE PROBLEMS
YES
Wire 9 faulty.
Connector J2 faulty.
Connector P2 faulty.
2-366
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |