TM 10-3930-673-20-1
14. FRONT FLOODLIGHT (OR FORWARD) DOES NOT OPERATE (CONT).
4
KNOWN INFO
TEST OPTIONS
Continuity test.
Is continuity present on
STE/ICE-R #88.
POSSIBLE PROBLEMS
negative battery cable?
REASON FOR QUESTION
Ground faulty.
Connector P2 faulty.
If continuity is not present,
Connector J2 faulty.
negative battery cable is faulty.
Wire 9 faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Repair negative
NO
Front floodlight switch faulty.
battery cable
(Para 8-44).
YES
Service or replace
battery (Para 8-42).
KNOWN INFO
TEST OPTIONS
5
Ground OK.
Voltage test.
Is 24 vdc present at
STE/ICE-R #89.
POSSIBLE PROBLEMS
connector P2 where wire 9
REASON FOR QUESTION
Connector P2 faulty.
connects?
Connector J2 faulty.
If voltage is not present, wire 9 or
Wire 9 faulty.
connector P2 is faulty.
Circuit breaker CB6 faulty.
Wire 1 faulty.
Run relay K1 faulty.
Wire 3 faulty.
Relay K2 faulty.
Wire 5 faulty.
Circuit breaker CB7 faulty.
Wire 70 faulty.
Front floodlight switch faulty.
Repair wire 9 or
NO
connector P2
(Para 8-49).
YES
2-248
|